| Model name | ENM-A10 | ENM-A12 | ENM-A24 | |
| Chamber | ||||
| Chamber material | STS316, 전해연마, 산처리 | |||
| Chamber Size(mm) | Length | 1368 | 2405 | |
| Height | 150 | 150 | ||
| Design Pressure | 10~15bar | |||
| Lamp | ||||
| Lamp Type | Medium Pressure UV Lamp | |||
| Lamp Power | 10kW | 12kW | 24kW | |
UV AOP is a process that generates radicals (typically OH radicals) using ultraviolet light and oxidizers to oxidize and decompose organic contaminants in water.

Medium-pressure UV AOP uses medium-pressure lamps capable of irradiating multiple UV wavelengths to remove various organic pollutants. This enables large-capacity water treatment with fewer lamps.